<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Multi Split System &#8211; Outdoor Unit &#8211; UK’s Premier Importer &amp; Distributor of Air Conditioning Systems</title>
	<atom:link href="https://www.airconditioningcentre.com/product-category/multi-split-systems-outdoor-unit/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.airconditioningcentre.com</link>
	<description></description>
	<lastBuildDate>Wed, 13 Aug 2025 13:49:28 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.3.18</generator>

<image>
	<url>https://www.airconditioningcentre.com/wp-content/uploads/2018/12/cropped-Website-tile-32x32.png</url>
	<title>Multi Split System &#8211; Outdoor Unit &#8211; UK’s Premier Importer &amp; Distributor of Air Conditioning Systems</title>
	<link>https://www.airconditioningcentre.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>iPAC-18-MOU 18000BTU 5Kw 1 Drive 2 OUTDOOR UNIT</title>
		<link>https://www.airconditioningcentre.com/product/ipac-18-mou-18000btu-5kw-1-drive-3-indoor-unit/</link>
				<comments>https://www.airconditioningcentre.com/product/ipac-18-mou-18000btu-5kw-1-drive-3-indoor-unit/#respond</comments>
				<pubDate>Fri, 21 Jun 2024 13:59:21 +0000</pubDate>
		<dc:creator><![CDATA[Pat Martin]]></dc:creator>
		
		<guid isPermaLink="false">https://www.airconditioningcentre.com/?post_type=product&#038;p=5421</guid>
				<description><![CDATA[iPAC-18-MOU 5Kw Outdoor Unit 18000 BTU Total Capacity Our EASYfit split air conditioning units are perfect for both residential and commercial use. The iPAC-18-MOU is a highly energy efficient, easy to install, multipurpose multi wall split unit and can be used all year round. It will keep your home or office cool and fresh during &#91;...&#93;]]></description>
								<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box hundred-percent-fullwidth non-hundred-percent-height-scrolling"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;border-top-width:0px;border-bottom-width:0px;border-color:#eae9e9;border-top-style:solid;border-bottom-style:solid;'><div class="fusion-builder-row fusion-row "><div  class="fusion-layout-column fusion_builder_column fusion_builder_column_1_1  fusion-one-full fusion-column-first fusion-column-last fusion-column-no-min-height 1_1"  style='margin-top:0px;margin-bottom:0px;'>
					<div class="fusion-column-wrapper" style="padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;"  data-bg-url="">
						<div class="fusion-tabs fusion-tabs-1 clean horizontal-tabs icon-position-left"><style type="text/css">#wrapper .fusion-tabs.fusion-tabs-1.clean .nav-tabs li a{border-color:#ebeaea;}.fusion-tabs.fusion-tabs-1 .nav-tabs li a{background-color:#ebeaea;}.fusion-tabs.fusion-tabs-1 .nav-tabs li.active a,.fusion-tabs.fusion-tabs-1 .nav-tabs li.active a:hover,.fusion-tabs.fusion-tabs-1 .nav-tabs li.active a:focus{background-color:#ffffff;}.fusion-tabs.fusion-tabs-1 .nav-tabs li a:hover{background-color:#ffffff;border-top-color:#ffffff;}.fusion-tabs.fusion-tabs-1 .tab-pane{background-color:#ffffff;}.fusion-tabs.fusion-tabs-1 .nav,.fusion-tabs.fusion-tabs-1 .nav-tabs,.fusion-tabs.fusion-tabs-1 .tab-content .tab-pane{border-color:#ebeaea;}</style><div class="nav"><ul class="nav-tabs nav-justified"><li class="active"><a class="tab-link" data-toggle="tab" id="fusion-tab-mix&amp;matchcombinations" href="#tab-4b7b178b248d3352a6f"><h4 class="fusion-tab-heading">Mix &amp; Match Combinations</h4></a></li><li><a class="tab-link" data-toggle="tab" id="fusion-tab-dimensions" href="#tab-77b3ae42dfedd43cff7"><h4 class="fusion-tab-heading">Dimensions</h4></a></li><li><a class="tab-link" data-toggle="tab" id="fusion-tab-techspecs" href="#tab-b08095b59bda04239db"><h4 class="fusion-tab-heading">Tech Specs</h4></a></li></ul></div><div class="tab-content"><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li class="active"><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-mix&amp;matchcombinations" href="#tab-4b7b178b248d3352a6f"><h4 class="fusion-tab-heading">Mix &amp; Match Combinations</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix in active" id="tab-4b7b178b248d3352a6f">
<h4><span style="color: #36454d;"><strong>Combinations for up to 3 Units</strong></span></h4>
<h4>1 Unit:</h4>
<ul>
<li>9000 BTU</li>
<li>12000 BTU</li>
<li>18000 BTU</li>
</ul>
<h4>2 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU</li>
<li>9000 BTU + 12000 BTU</li>
<li>9000 BTU + 18000 BTU</li>
<li>12000 BTU + 12000 BTU</li>
<li>12000 BTU + 18000 BTU</li>
<li>18000 BTU + 18000 BTU</li>
</ul>
<h4>3 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU + 9000 BTU</li>
<li>9000 BTU + 9000 BTU + 12000 BTU</li>
<li>9000 BTU + 9000 BTU + 18000 BTU</li>
<li>9000 BTU + 12000 BTU + 12000 BTU</li>
<li>9000 BTU + 12000 BTU + 18000 BTU</li>
<li>12000 BTU + 12000 BTU + 12000 BTU</li>
</ul>
<h4>Where</h4>
<ul>
<li>9000 BTU= KFR-23IW/X1c-MIU</li>
<li>12000 BTU=KFR-33IW/X1c-MIU¸ KFR-37CIW/X1c-MIU</li>
<li>18000 BTU=KFR-53IW/X1c-MIU¸ KFR-57CIW/X1c-MIU¸ KFR-50QIW/X1c-MIU</li>
</ul>
<p><strong>*Each indoor unit can run up 20 meters pipe to outdoor unit <em>(Additional Refrigerant Required)</em></strong></p>
<p><strong>*Total pipe run can run up to 45 meters <em>(Additional Refrigerant Required)</em></strong></p>
</div><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-dimensions" href="#tab-77b3ae42dfedd43cff7"><h4 class="fusion-tab-heading">Dimensions</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix" id="tab-77b3ae42dfedd43cff7">
<table width="530">
<tbody>
<tr>
<td rowspan="3" width="135">Outdoor unit</td>
<td width="134">Dimension(WxDxH)</td>
<td width="61">mm</td>
<td width="200">805*330*554</td>
</tr>
<tr>
<td>Packing(WxDxH)</td>
<td width="61">mm</td>
<td>915*370*615</td>
</tr>
<tr>
<td>Net/Gross weight</td>
<td width="61">kg</td>
<td width="200">35/38</td>
</tr>
</tbody>
</table>
</div><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-techspecs" href="#tab-b08095b59bda04239db"><h4 class="fusion-tab-heading">Tech Specs</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix" id="tab-b08095b59bda04239db">
<p><strong>NOTE:</strong> For multi-split type air conditioners, one outdoor unit can be matched to different types of indoor units. All of the<br />
pictures in this manual are for demonstration purposes only. Your air conditioner may be slightly different, if similar in<br />
shape. The following pages introduce several kinds of indoor units that can be matched with the outdoor units.</p>
<p><strong>Operating Conditions</strong><br />
Use the system under the following temperatures for safe and effective operation. If the air conditioner is used under<br />
different conditions, it may malfunction or become less efficient.</p>
<table width="530">
<tbody>
<tr>
<td colspan="3" width="330">Outdoor Model</td>
<td width="200">iPAC-18-MOU</td>
</tr>
<tr>
<td colspan="3">Outdoor Code</td>
<td>22022316001525</td>
</tr>
<tr>
<td colspan="2">Power supply</td>
<td width="61">V,Hz,Ph</td>
<td>220-240V,1Ph,50Hz</td>
</tr>
<tr>
<td rowspan="4">Cooling</td>
<td>Capacity</td>
<td>Btu/h</td>
<td>18000（7800~19500)</td>
</tr>
<tr>
<td>Input</td>
<td>W</td>
<td>1635（690~2000)</td>
</tr>
<tr>
<td>Rated current</td>
<td>A</td>
<td>7.3（3.2~9.0)</td>
</tr>
<tr>
<td>EER</td>
<td>W/W</td>
<td>3.23</td>
</tr>
<tr>
<td rowspan="4">Heating</td>
<td>Capacity</td>
<td>Btu/h</td>
<td>19000（8200~19600)</td>
</tr>
<tr>
<td>Input</td>
<td>W</td>
<td>1500（600~1780)</td>
</tr>
<tr>
<td>Rated current</td>
<td>A</td>
<td>6.6（2.80~7.95)</td>
</tr>
<tr>
<td>COP</td>
<td>W/W</td>
<td>3.71</td>
</tr>
<tr>
<td rowspan="3">Seasonal Cooling</td>
<td>Pdesignc</td>
<td>kW</td>
<td>5.3</td>
</tr>
<tr>
<td>SEER</td>
<td>W/W</td>
<td>6.1</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A++</td>
</tr>
<tr>
<td rowspan="4">Heating(Average )</td>
<td>Pdesignh</td>
<td>kW</td>
<td>4.8</td>
</tr>
<tr>
<td>SCOP</td>
<td>W/W</td>
<td>3.8</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A</td>
</tr>
<tr>
<td>Tbiv</td>
<td>℃</td>
<td>-7</td>
</tr>
<tr>
<td rowspan="4">Heating(Warmer )</td>
<td>Pdesignh</td>
<td>kW</td>
<td>5.0</td>
</tr>
<tr>
<td>SCOP</td>
<td>W/W</td>
<td>5.1</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A+++</td>
</tr>
<tr>
<td>Tbiv</td>
<td>℃</td>
<td>2</td>
</tr>
<tr>
<td colspan="2">Tol</td>
<td>℃</td>
<td>-15</td>
</tr>
<tr>
<td colspan="2" width="269">Max. input consumption</td>
<td width="61">W</td>
<td>3050</td>
</tr>
<tr>
<td colspan="2" width="269">Max. input current</td>
<td width="61">A</td>
<td>13</td>
</tr>
<tr>
<td rowspan="10" width="135">Compressor</td>
<td>Model</td>
<td width="61"></td>
<td>KSN140D58UFZ</td>
</tr>
<tr>
<td>Type</td>
<td width="61"></td>
<td>ROTARY</td>
</tr>
<tr>
<td>Brand</td>
<td width="61"></td>
<td>GMCC</td>
</tr>
<tr>
<td>Capacity</td>
<td width="61">Btu/h</td>
<td>4315</td>
</tr>
<tr>
<td>Input</td>
<td width="61">W</td>
<td>1090</td>
</tr>
<tr>
<td>Rated current(RLA)</td>
<td width="61">A</td>
<td>7.15</td>
</tr>
<tr>
<td>Locked rotor Amp(LRA)</td>
<td width="61">A</td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Thermal protector position</td>
<td width="61"></td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Capacitor</td>
<td width="61">μF</td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Refrigerant oil</td>
<td width="61">ml</td>
<td>VG74 440</td>
</tr>
<tr>
<td rowspan="6" width="135">Outdoor fan motor</td>
<td>New Model</td>
<td width="61"></td>
<td>ZKFN-34-10-1-3</td>
</tr>
<tr>
<td>Model</td>
<td width="61"></td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Qty</td>
<td width="61"></td>
<td>1</td>
</tr>
<tr>
<td>Output</td>
<td width="61">W</td>
<td>47</td>
</tr>
<tr>
<td>Capacitor</td>
<td width="61">μF</td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Speed(Hi/Med/Lo)</td>
<td width="61">r/min</td>
<td>760/700/500</td>
</tr>
<tr>
<td rowspan="7" width="135">Outdoor coil</td>
<td>Number of rows</td>
<td width="61"></td>
<td>2</td>
</tr>
<tr>
<td>Tube pitch(a)* row pitch(b)</td>
<td width="61">mm</td>
<td>21&#215;22</td>
</tr>
<tr>
<td>Fin spacing</td>
<td width="61">mm</td>
<td>1.3</td>
</tr>
<tr>
<td>Fin type</td>
<td width="61"></td>
<td>Hydrophilic aluminium(Golden)</td>
</tr>
<tr>
<td>Tube outside dia.and type</td>
<td width="61">mm</td>
<td>Φ7,innergroove tube</td>
</tr>
<tr>
<td>Coil length * height * width</td>
<td width="61">mm</td>
<td>860*504*44</td>
</tr>
<tr>
<td>Number of circuits</td>
<td width="61"></td>
<td>4</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor air flow</td>
<td>m3/h</td>
<td>2100</td>
</tr>
<tr>
<td colspan="2">Indoor sound power level</td>
<td>dB(A)</td>
<td>54</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor  sound pressure level</td>
<td>dB(A)</td>
<td>54</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor sound power level</td>
<td>dB(A)</td>
<td>65</td>
</tr>
<tr>
<td colspan="2" width="269">Throttle type</td>
<td width="61"></td>
<td>EXV+Capillary</td>
</tr>
<tr>
<td rowspan="3" width="135">Outdoor unit</td>
<td>Dimension(WxDxH)</td>
<td width="61">mm</td>
<td>805*330*554</td>
</tr>
<tr>
<td>Packing(WxDxH)</td>
<td width="61">mm</td>
<td>915*370*615</td>
</tr>
<tr>
<td>Net/Gross weight</td>
<td width="61">kg</td>
<td width="200">35/38</td>
</tr>
<tr>
<td rowspan="3">Refrigerant</td>
<td>Type</td>
<td></td>
<td>R32</td>
</tr>
<tr>
<td>GWP</td>
<td></td>
<td>675</td>
</tr>
<tr>
<td>Charged quantity</td>
<td>Kg</td>
<td>1.25</td>
</tr>
<tr>
<td colspan="2" width="269">Design pressure</td>
<td width="61">MPa</td>
<td>4.3/1.7</td>
</tr>
<tr>
<td rowspan="5" width="135">Refrigerant piping</td>
<td width="134">Liquid side/ Gas side</td>
<td width="61">mm(inch)</td>
<td>2&#215;6.35mm(2&#215;1/4in)/2&#215;9.52mm(2&#215;3/8in)</td>
</tr>
<tr>
<td width="134">Max. length for all rooms</td>
<td width="61">m</td>
<td>40</td>
</tr>
<tr>
<td width="134">Max. length for one indoor unit</td>
<td width="61">m</td>
<td>25</td>
</tr>
<tr>
<td width="134">Max. height difference between indoor and outdoor unit</td>
<td width="61">m</td>
<td>15</td>
</tr>
<tr>
<td width="134">Max. height difference between indoor units</td>
<td width="61">m</td>
<td>10</td>
</tr>
<tr>
<td rowspan="2" width="135">Ambient temperature</td>
<td>Cooling</td>
<td width="61">℃</td>
<td>-15-50</td>
</tr>
<tr>
<td>Heating</td>
<td width="61">℃</td>
<td>-15-24</td>
</tr>
</tbody>
</table>
</div></div></div><div class="fusion-clearfix"></div>

					</div>
				</div></div></div>
]]></content:encoded>
							<wfw:commentRss>https://www.airconditioningcentre.com/product/ipac-18-mou-18000btu-5kw-1-drive-3-indoor-unit/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>iPAC-42-MOU 42000BTU 12Kw 1 Drive 5 OUTDOOR UNIT</title>
		<link>https://www.airconditioningcentre.com/product/5-head-outdoor-unit-43000-btu-total-capacity/</link>
				<comments>https://www.airconditioningcentre.com/product/5-head-outdoor-unit-43000-btu-total-capacity/#respond</comments>
				<pubDate>Sat, 31 Jan 2015 05:42:13 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
		
		<guid isPermaLink="false">http://bwishh.tk/airconditioningcentre/product/kms5mioxic/</guid>
				<description><![CDATA[iPAC-42-MOU 12Kw Outdoor Unit 42000 BTU Total Capacity Our EASYfit split air conditioning units are perfect for both residential and commercial use. The iPAC-42-MOU is a highly energy efficient, easy to install, multipurpose multi wall split unit and can be used all year round. It will keep your home or office cool and fresh during &#91;...&#93;]]></description>
								<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box hundred-percent-fullwidth non-hundred-percent-height-scrolling"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;border-top-width:0px;border-bottom-width:0px;border-color:#eae9e9;border-top-style:solid;border-bottom-style:solid;'><div class="fusion-builder-row fusion-row "><div  class="fusion-layout-column fusion_builder_column fusion_builder_column_1_1  fusion-one-full fusion-column-first fusion-column-last fusion-column-no-min-height 1_1"  style='margin-top:0px;margin-bottom:0px;'>
					<div class="fusion-column-wrapper" style="padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;"  data-bg-url="">
						<div class="fusion-tabs fusion-tabs-2 clean horizontal-tabs icon-position-left"><style type="text/css">#wrapper .fusion-tabs.fusion-tabs-2.clean .nav-tabs li a{border-color:#ebeaea;}.fusion-tabs.fusion-tabs-2 .nav-tabs li a{background-color:#ebeaea;}.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a,.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a:hover,.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a:focus{background-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .nav-tabs li a:hover{background-color:#ffffff;border-top-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .tab-pane{background-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .nav,.fusion-tabs.fusion-tabs-2 .nav-tabs,.fusion-tabs.fusion-tabs-2 .tab-content .tab-pane{border-color:#ebeaea;}</style><div class="nav"><ul class="nav-tabs nav-justified"><li class="active"><a class="tab-link" data-toggle="tab" id="fusion-tab-mix&amp;matchcombinations" href="#tab-8d085cc043ff9e6fb15"><h4 class="fusion-tab-heading">Mix &amp; Match Combinations</h4></a></li><li><a class="tab-link" data-toggle="tab" id="fusion-tab-dimensions" href="#tab-7a75ce194dc27dc65f8"><h4 class="fusion-tab-heading">Dimensions</h4></a></li><li><a class="tab-link" data-toggle="tab" id="fusion-tab-techspecs" href="#tab-a46b3505667f8a5a4f3"><h4 class="fusion-tab-heading">Tech Specs</h4></a></li></ul></div><div class="tab-content"><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li class="active"><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-mix&amp;matchcombinations" href="#tab-8d085cc043ff9e6fb15"><h4 class="fusion-tab-heading">Mix &amp; Match Combinations</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix in active" id="tab-8d085cc043ff9e6fb15">
<h4><span style="color: #36454d;"><strong>Combinations for up to 5 Units</strong></span></h4>
<h4>1 Unit:</h4>
<ul>
<li>9000 BTU</li>
<li>12000 BTU</li>
<li>18000 BTU</li>
</ul>
<h4>2 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU</li>
<li>9000 BTU + 12000 BTU</li>
<li>9000 BTU + 18000 BTU</li>
<li>12000 BTU + 12000 BTU</li>
<li>12000 BTU + 18000 BTU</li>
<li>18000 BTU + 18000 BTU</li>
</ul>
<h4>3 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU + 9000 BTU</li>
<li>9000 BTU + 9000 BTU + 12000 BTU</li>
<li>9000 BTU + 9000 BTU + 18000 BTU</li>
<li>9000 BTU + 12000 BTU + 12000 BTU</li>
<li>9000 BTU + 12000 BTU + 18000 BTU</li>
<li>12000 BTU + 12000 BTU + 12000 BTU</li>
</ul>
<h4>4 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU + 9000 BTU + 9000 BTU</li>
<li>9000 BTU + 9000 BTU + 9000 BTU + 12000 BTU</li>
<li>9000 BTU+ 9000 BTU + 9000 BTU + 18000 BTU</li>
<li>9000 BTU + 9000 BTU + 12000 BTU + 12000 BTU</li>
<li>9000 BTU + 9000 BTU + 12000 BTU + 18000 BTU</li>
<li>9000 BTU + 9000 BTU + 18000 BTU +18000 BTU</li>
<li>9000 BTU + 12000 BTU + 12000 BTU+ 12000 BTU</li>
<li>9000 BTU + 12000 BTU + 12000 BTU+ 18000 BTU</li>
<li>12000 BTU + 12000 BTU + 12000 BTU + 12000 BTU</li>
<li>12000 BTU + 12000 BTU + 12000 BTU + 18000 BTU</li>
</ul>
<h4>5 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU + 9000 BTU + 9000 BTU + 9000 BTU</li>
<li>9000 BTU + 9000 BTU + 9000 BTU + 9000 BTU + 12000 BTU</li>
<li>9000 BTU + 9000 BTU + 9000 BTU + 9000 BTU + 18000 BTU</li>
<li>9000 BTU + 9000 BTU + 9000 BTU + 12000 BTU + 12000 BTU</li>
<li>9000 BTU + 9000 BTU + 9000 BTU + 12000 BTU + 18000 BTU</li>
<li>9000 BTU + 9000 BTU + 12000 BTU + 12000 BTU + 12000 BTU</li>
<li>9000 BTU + 12000 BTU + 12000 BTU + 12000 BTU + 12000 BTU</li>
<li>12000 BTU + 12000 BTU + 12000 BTU + 12000 BTU + 12000 BTU</li>
</ul>
<h4>Where</h4>
<ul>
<li>9000 BTU= KFR-23IW/X1c-MIU</li>
<li>12000 BTU=KFR-33IW/X1c-MIU¸ KFR-37CIW/X1c-MIU</li>
<li>18000 BTU=KFR-53IW/X1c-MIU¸ KFR-57CIW/X1c-MIU¸ KFR-50QIW/X1c-MIU</li>
</ul>
<p><strong>*Each indoor unit can run up 25 meters pipe to outdoor unit <em>(Additional Refrigerant Required)</em></strong></p>
<p><strong>*Total pipe run can run up to 75 meters <em>(Additional Refrigerant Required)</em></strong></p>
</div><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-dimensions" href="#tab-7a75ce194dc27dc65f8"><h4 class="fusion-tab-heading">Dimensions</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix" id="tab-7a75ce194dc27dc65f8">
<table width="530">
<tbody>
<tr>
<td rowspan="3" width="135">Outdoor unit</td>
<td width="134">Dimension(WxDxH)</td>
<td width="61">mm</td>
<td width="200">946x410x810</td>
</tr>
<tr>
<td>Packing(WxDxH)</td>
<td width="61">mm</td>
<td>1090x500x885</td>
</tr>
<tr>
<td>Net/Gross weight</td>
<td width="61">kg</td>
<td>74.1/79.5</td>
</tr>
</tbody>
</table>
</div><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-techspecs" href="#tab-a46b3505667f8a5a4f3"><h4 class="fusion-tab-heading">Tech Specs</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix" id="tab-a46b3505667f8a5a4f3">
<p><strong>NOTE:</strong> For multi-split type air conditioners, one outdoor unit can be matched to different types of indoor units. All of the<br />
pictures in this manual are for demonstration purposes only. Your air conditioner may be slightly different, if similar in<br />
shape. The following pages introduce several kinds of indoor units that can be matched with the outdoor units.</p>
<p><strong>Operating Conditions</strong><br />
Use the system under the following temperatures for safe and effective operation. If the air conditioner is used under<br />
different conditions, it may malfunction or become less efficient.</p>
<table width="530">
<tbody>
<tr>
<td colspan="3" width="330">Outdoor Model</td>
<td width="200">iPAC-42-MOU</td>
</tr>
<tr>
<td colspan="3">Outdoor Code</td>
<td>22022316001325</td>
</tr>
<tr>
<td colspan="2">Power supply</td>
<td width="61">V,Hz,Ph</td>
<td>220-240V,1Ph,50Hz</td>
</tr>
<tr>
<td rowspan="4">Cooling</td>
<td>Capacity</td>
<td>Btu/h</td>
<td>42000（10300~42000)</td>
</tr>
<tr>
<td>Input</td>
<td>W</td>
<td>3810（280~4650)</td>
</tr>
<tr>
<td>Rated current</td>
<td>A</td>
<td>16（1.4~20.7)</td>
</tr>
<tr>
<td>EER</td>
<td>W/W</td>
<td>3</td>
</tr>
<tr>
<td rowspan="4">Heating</td>
<td>Capacity</td>
<td>Btu/h</td>
<td>42000（11800~42000)</td>
</tr>
<tr>
<td>Input</td>
<td>W</td>
<td>3300（650~3800)</td>
</tr>
<tr>
<td>Rated current</td>
<td>A</td>
<td>14.6（3.0~16.6)</td>
</tr>
<tr>
<td>COP</td>
<td>W/W</td>
<td>4</td>
</tr>
<tr>
<td rowspan="3">Seasonal Cooling</td>
<td>Pdesignc</td>
<td>kW</td>
<td>12</td>
</tr>
<tr>
<td>SEER</td>
<td>W/W</td>
<td>6</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A++</td>
</tr>
<tr>
<td rowspan="4">Heating(Average )</td>
<td>Pdesignh</td>
<td>kW</td>
<td>10</td>
</tr>
<tr>
<td>SCOP</td>
<td>W/W</td>
<td>4</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A</td>
</tr>
<tr>
<td>Tbiv</td>
<td>℃</td>
<td>(7)</td>
</tr>
<tr>
<td rowspan="4">Heating(Warmer )</td>
<td>Pdesignh</td>
<td>kW</td>
<td>10</td>
</tr>
<tr>
<td>SCOP</td>
<td>W/W</td>
<td>4.9</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A++</td>
</tr>
<tr>
<td>Tbiv</td>
<td>℃</td>
<td>2</td>
</tr>
<tr>
<td colspan="2">Tol</td>
<td>℃</td>
<td>(15)</td>
</tr>
<tr>
<td colspan="2" width="269">Max. input consumption</td>
<td width="61">W</td>
<td>4700</td>
</tr>
<tr>
<td colspan="2" width="269">Max. input current</td>
<td width="61">A</td>
<td>22.0</td>
</tr>
<tr>
<td rowspan="10" width="135">Compressor</td>
<td>Model</td>
<td width="61"></td>
<td>KTF310D43UMT</td>
</tr>
<tr>
<td>Type</td>
<td width="61"></td>
<td>ROTARY</td>
</tr>
<tr>
<td>Brand</td>
<td width="61"></td>
<td>GMCC</td>
</tr>
<tr>
<td>Capacity</td>
<td width="61">Btu/h</td>
<td>10010</td>
</tr>
<tr>
<td>Input</td>
<td width="61">W</td>
<td>2765</td>
</tr>
<tr>
<td>Rated current(RLA)</td>
<td width="61">A</td>
<td>5</td>
</tr>
<tr>
<td>Locked rotor Amp(LRA)</td>
<td width="61">A</td>
<td>/</td>
</tr>
<tr>
<td>Thermal protector position</td>
<td width="61"></td>
<td>INT01L-4639</td>
</tr>
<tr>
<td>Capacitor</td>
<td width="61">μF</td>
<td>EXTERNAL</td>
</tr>
<tr>
<td>Refrigerant oil</td>
<td width="61">ml</td>
<td>/</td>
</tr>
<tr>
<td rowspan="6" width="135">Outdoor fan motor</td>
<td>New Model</td>
<td width="61"></td>
<td>VG74/1000</td>
</tr>
<tr>
<td>Model</td>
<td width="61"></td>
<td>ZKFN-120-8-2</td>
</tr>
<tr>
<td>Qty</td>
<td width="61"></td>
<td>1</td>
</tr>
<tr>
<td>Output</td>
<td width="61">W</td>
<td>150.0</td>
</tr>
<tr>
<td>Capacitor</td>
<td width="61">μF</td>
<td>/</td>
</tr>
<tr>
<td>Speed(Hi/Med/Lo)</td>
<td width="61">r/min</td>
<td>2</td>
</tr>
<tr>
<td rowspan="7" width="135">Outdoor coil</td>
<td>Number of rows</td>
<td width="61"></td>
<td>3</td>
</tr>
<tr>
<td>Tube pitch(a)* row pitch(b)</td>
<td width="61">mm</td>
<td>25.4&#215;22</td>
</tr>
<tr>
<td>Fin spacing</td>
<td width="61">mm</td>
<td>1.3</td>
</tr>
<tr>
<td>Fin type</td>
<td width="61"></td>
<td>Hydrophilic aluminum</td>
</tr>
<tr>
<td>Tube outside dia.and type</td>
<td width="61">mm</td>
<td>Φ9.52,Inner groove tube</td>
</tr>
<tr>
<td>Coil length * height * width</td>
<td width="61">mm</td>
<td>995x762x22+960x762x22+580x762x22</td>
</tr>
<tr>
<td>Number of circuits</td>
<td width="61"></td>
<td>4</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor air flow</td>
<td>m3/h</td>
<td>3850</td>
</tr>
<tr>
<td colspan="2">Indoor sound power level</td>
<td>dB(A)</td>
<td>55</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor  sound pressure level</td>
<td>dB(A)</td>
<td>64.0</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor sound power level</td>
<td>dB(A)</td>
<td>69.0</td>
</tr>
<tr>
<td colspan="2" width="269">Throttle type</td>
<td width="61"></td>
<td>EXV+Capillary</td>
</tr>
<tr>
<td rowspan="3" width="135">Outdoor unit</td>
<td>Dimension(WxDxH)</td>
<td width="61">mm</td>
<td>946x410x810</td>
</tr>
<tr>
<td>Packing(WxDxH)</td>
<td width="61">mm</td>
<td>1090x500x885</td>
</tr>
<tr>
<td>Net/Gross weight</td>
<td width="61">kg</td>
<td>74.1/79.5</td>
</tr>
<tr>
<td rowspan="3">Refrigerant</td>
<td>Type</td>
<td></td>
<td>R32</td>
</tr>
<tr>
<td>GWP</td>
<td></td>
<td>675</td>
</tr>
<tr>
<td>Charged quantity</td>
<td>Kg</td>
<td>3</td>
</tr>
<tr>
<td colspan="2" width="269">Design pressure</td>
<td width="61">MPa</td>
<td>4.3/1.7</td>
</tr>
<tr>
<td rowspan="5" width="135">Refrigerant piping</td>
<td width="134">Liquid side/ Gas side</td>
<td width="61">mm(inch)</td>
<td width="200">5&#215;6.35mm(5&#215;1/4in)/4&#215;9.52mm+1&#215;12.7mm(4&#215;3/8in+1&#215;1/2in)</td>
</tr>
<tr>
<td width="134">Max. length for all rooms</td>
<td width="61">m</td>
<td>80</td>
</tr>
<tr>
<td width="134">Max. length for one indoor unit</td>
<td width="61">m</td>
<td>35</td>
</tr>
<tr>
<td width="134">Max. height difference between indoor and outdoor unit</td>
<td width="61">m</td>
<td>15</td>
</tr>
<tr>
<td width="134">Max. height difference between indoor units</td>
<td width="61">m</td>
<td>10</td>
</tr>
<tr>
<td rowspan="2" width="135">Ambient temperature</td>
<td>Cooling</td>
<td width="61">℃</td>
<td>-15-50</td>
</tr>
<tr>
<td>Heating</td>
<td width="61">℃</td>
<td>-15-24</td>
</tr>
</tbody>
</table>
</div></div></div><div class="fusion-clearfix"></div>

					</div>
				</div></div></div>
]]></content:encoded>
							<wfw:commentRss>https://www.airconditioningcentre.com/product/5-head-outdoor-unit-43000-btu-total-capacity/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>iPAC-27-MOU 27000BTU 9Kw 1 Drive 3 OUTDOOR UNIT</title>
		<link>https://www.airconditioningcentre.com/product/3-head-outdoor-unit-27000-btu-total-capacity/</link>
				<comments>https://www.airconditioningcentre.com/product/3-head-outdoor-unit-27000-btu-total-capacity/#respond</comments>
				<pubDate>Sat, 31 Jan 2015 05:36:37 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
		
		<guid isPermaLink="false">http://bwishh.tk/airconditioningcentre/product/kms3miox1c/</guid>
				<description><![CDATA[iPAC-27-MOU 9Kw Outdoor Unit 27000 BTU Total Capacity Our EASYfit split air conditioning units are perfect for both residential and commercial use. The iPAC-27-MOU is a highly energy efficient, easy to install, multipurpose multi wall split unit and can be used all year round. It will keep your home or office cool and fresh during &#91;...&#93;]]></description>
								<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box hundred-percent-fullwidth non-hundred-percent-height-scrolling"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;border-top-width:0px;border-bottom-width:0px;border-color:#eae9e9;border-top-style:solid;border-bottom-style:solid;'><div class="fusion-builder-row fusion-row "><div  class="fusion-layout-column fusion_builder_column fusion_builder_column_1_1  fusion-one-full fusion-column-first fusion-column-last fusion-column-no-min-height 1_1"  style='margin-top:0px;margin-bottom:0px;'>
					<div class="fusion-column-wrapper" style="padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;"  data-bg-url="">
						<div class="fusion-tabs fusion-tabs-3 clean horizontal-tabs icon-position-left"><style type="text/css">#wrapper .fusion-tabs.fusion-tabs-3.clean .nav-tabs li a{border-color:#ebeaea;}.fusion-tabs.fusion-tabs-3 .nav-tabs li a{background-color:#ebeaea;}.fusion-tabs.fusion-tabs-3 .nav-tabs li.active a,.fusion-tabs.fusion-tabs-3 .nav-tabs li.active a:hover,.fusion-tabs.fusion-tabs-3 .nav-tabs li.active a:focus{background-color:#ffffff;}.fusion-tabs.fusion-tabs-3 .nav-tabs li a:hover{background-color:#ffffff;border-top-color:#ffffff;}.fusion-tabs.fusion-tabs-3 .tab-pane{background-color:#ffffff;}.fusion-tabs.fusion-tabs-3 .nav,.fusion-tabs.fusion-tabs-3 .nav-tabs,.fusion-tabs.fusion-tabs-3 .tab-content .tab-pane{border-color:#ebeaea;}</style><div class="nav"><ul class="nav-tabs nav-justified"><li class="active"><a class="tab-link" data-toggle="tab" id="fusion-tab-mix&amp;matchcombinations" href="#tab-6a7d1afaefdfc2643f7"><h4 class="fusion-tab-heading">Mix &amp; Match Combinations</h4></a></li><li><a class="tab-link" data-toggle="tab" id="fusion-tab-dimensions" href="#tab-c7976c1d5f204e532f7"><h4 class="fusion-tab-heading">Dimensions</h4></a></li><li><a class="tab-link" data-toggle="tab" id="fusion-tab-techspecs" href="#tab-c78793913fd31a514ea"><h4 class="fusion-tab-heading">Tech Specs</h4></a></li></ul></div><div class="tab-content"><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li class="active"><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-mix&amp;matchcombinations" href="#tab-6a7d1afaefdfc2643f7"><h4 class="fusion-tab-heading">Mix &amp; Match Combinations</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix in active" id="tab-6a7d1afaefdfc2643f7">
<h4><span style="color: #36454d;"><strong>Combinations for up to 3 Units</strong></span></h4>
<h4>1 Unit:</h4>
<ul>
<li>9000 BTU</li>
<li>12000 BTU</li>
<li>18000 BTU</li>
</ul>
<h4>2 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU</li>
<li>9000 BTU + 12000 BTU</li>
<li>9000 BTU + 18000 BTU</li>
<li>12000 BTU + 12000 BTU</li>
<li>12000 BTU + 18000 BTU</li>
<li>18000 BTU + 18000 BTU</li>
</ul>
<h4>3 Units:</h4>
<ul>
<li>9000 BTU + 9000 BTU + 9000 BTU</li>
<li>9000 BTU + 9000 BTU + 12000 BTU</li>
<li>9000 BTU + 9000 BTU + 18000 BTU</li>
<li>9000 BTU + 12000 BTU + 12000 BTU</li>
<li>9000 BTU + 12000 BTU + 18000 BTU</li>
<li>12000 BTU + 12000 BTU + 12000 BTU</li>
</ul>
<h4>Where</h4>
<ul>
<li>9000 BTU= KFR-23IW/X1c-MIU</li>
<li>12000 BTU=KFR-33IW/X1c-MIU¸ KFR-37CIW/X1c-MIU</li>
<li>18000 BTU=KFR-53IW/X1c-MIU¸ KFR-57CIW/X1c-MIU¸ KFR-50QIW/X1c-MIU</li>
</ul>
<p><strong>*Each indoor unit can run up 20 meters pipe to outdoor unit <em>(Additional Refrigerant Required)</em></strong></p>
<p><strong>*Total pipe run can run up to 45 meters <em>(Additional Refrigerant Required)</em></strong></p>
</div><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-dimensions" href="#tab-c7976c1d5f204e532f7"><h4 class="fusion-tab-heading">Dimensions</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix" id="tab-c7976c1d5f204e532f7">
<table width="530">
<tbody>
<tr>
<td rowspan="3" width="135">Outdoor unit</td>
<td width="134">Dimension(WxDxH)</td>
<td width="61">mm</td>
<td width="200">890*342*673</td>
</tr>
<tr>
<td>Packing(WxDxH)</td>
<td width="61">mm</td>
<td width="200">1030*438*750</td>
</tr>
<tr>
<td>Net/Gross weight</td>
<td width="61">kg</td>
<td>48/51.8</td>
</tr>
</tbody>
</table>
</div><div class="nav fusion-mobile-tab-nav"><ul class="nav-tabs nav-justified"><li><a class="tab-link" data-toggle="tab" id="mobile-fusion-tab-techspecs" href="#tab-c78793913fd31a514ea"><h4 class="fusion-tab-heading">Tech Specs</h4></a></li></ul></div><div class="tab-pane fade fusion-clearfix" id="tab-c78793913fd31a514ea">
<p><strong>NOTE:</strong> For multi-split type air conditioners, one outdoor unit can be matched to different types of indoor units. All of the<br />
pictures in this manual are for demonstration purposes only. Your air conditioner may be slightly different, if similar in<br />
shape. The following pages introduce several kinds of indoor units that can be matched with the outdoor units.</p>
<p><strong>Operating Conditions</strong><br />
Use the system under the following temperatures for safe and effective operation. If the air conditioner is used under<br />
different conditions, it may malfunction or become less efficient.</p>
<table width="530">
<tbody>
<tr>
<td colspan="3" width="330">Outdoor Model</td>
<td width="200">iPAC-27-MOU</td>
</tr>
<tr>
<td colspan="3">Outdoor Code</td>
<td>22022316001465</td>
</tr>
<tr>
<td colspan="2">Power supply</td>
<td width="61">V,Hz,Ph</td>
<td>220-240V,50Hz,1Ph</td>
</tr>
<tr>
<td rowspan="4">Cooling</td>
<td>Capacity</td>
<td>Btu/h</td>
<td>27000(10850~28000)</td>
</tr>
<tr>
<td>Input</td>
<td>W</td>
<td>2450(290~3100)</td>
</tr>
<tr>
<td>Rated current</td>
<td>A</td>
<td>11.2(2.0~13.5)</td>
</tr>
<tr>
<td>EER</td>
<td>W/W</td>
<td>3.23</td>
</tr>
<tr>
<td rowspan="4">Heating</td>
<td>Capacity</td>
<td>Btu/h</td>
<td>28000(7800~29000)</td>
</tr>
<tr>
<td>Input</td>
<td>W</td>
<td>2210(370~2900)</td>
</tr>
<tr>
<td>Rated current</td>
<td>A</td>
<td>10.1(2.4~13)</td>
</tr>
<tr>
<td>COP</td>
<td>W/W</td>
<td>3.71</td>
</tr>
<tr>
<td rowspan="3">Seasonal Cooling</td>
<td>Pdesignc</td>
<td>kW</td>
<td>7.9</td>
</tr>
<tr>
<td>SEER</td>
<td>W/W</td>
<td>6.1</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A++</td>
</tr>
<tr>
<td rowspan="4">Heating(Average )</td>
<td>Pdesignh</td>
<td>kW</td>
<td>5.6</td>
</tr>
<tr>
<td>SCOP</td>
<td>W/W</td>
<td>4.0</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A+</td>
</tr>
<tr>
<td>Tbiv</td>
<td>℃</td>
<td>-7</td>
</tr>
<tr>
<td rowspan="4">Heating(Warmer )</td>
<td>Pdesignh</td>
<td>kW</td>
<td>6.1</td>
</tr>
<tr>
<td>SCOP</td>
<td>W/W</td>
<td>5.1</td>
</tr>
<tr>
<td>Energy Efficiency Class</td>
<td></td>
<td>A+++</td>
</tr>
<tr>
<td>Tbiv</td>
<td>℃</td>
<td>2</td>
</tr>
<tr>
<td colspan="2">Tol</td>
<td>℃</td>
<td>-15</td>
</tr>
<tr>
<td colspan="2" width="269">Max. input consumption</td>
<td width="61">W</td>
<td>4100</td>
</tr>
<tr>
<td colspan="2" width="269">Max. input current</td>
<td width="61">A</td>
<td>18</td>
</tr>
<tr>
<td rowspan="10" width="135">Compressor</td>
<td>Model</td>
<td width="61"></td>
<td>KTM240D57UMT</td>
</tr>
<tr>
<td>Type</td>
<td width="61"></td>
<td>Twin-ROTARY</td>
</tr>
<tr>
<td>Brand</td>
<td width="61"></td>
<td>GMCC</td>
</tr>
<tr>
<td>Capacity</td>
<td width="61">Btu/h</td>
<td>7740</td>
</tr>
<tr>
<td>Input</td>
<td width="61">W</td>
<td>2085</td>
</tr>
<tr>
<td>Rated current(RLA)</td>
<td width="61">A</td>
<td>9.45</td>
</tr>
<tr>
<td>Locked rotor Amp(LRA)</td>
<td width="61">A</td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Thermal protector position</td>
<td width="61"></td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Capacitor</td>
<td width="61">μF</td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Refrigerant oil</td>
<td width="61">ml</td>
<td>VG74/670</td>
</tr>
<tr>
<td rowspan="6" width="135">Outdoor fan motor</td>
<td>New Model</td>
<td width="61"></td>
<td>ZKFN-80-8-3</td>
</tr>
<tr>
<td>Model</td>
<td width="61"></td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Qty</td>
<td width="61"></td>
<td>1</td>
</tr>
<tr>
<td>Output</td>
<td width="61">W</td>
<td>88.0</td>
</tr>
<tr>
<td>Capacitor</td>
<td width="61">μF</td>
<td>&#8212;-</td>
</tr>
<tr>
<td>Speed(Hi/Med/Lo)</td>
<td width="61">r/min</td>
<td>1</td>
</tr>
<tr>
<td rowspan="7" width="135">Outdoor coil</td>
<td>Number of rows</td>
<td width="61"></td>
<td>2</td>
</tr>
<tr>
<td>Tube pitch(a)* row pitch(b)</td>
<td width="61">mm</td>
<td>21&#215;13.37</td>
</tr>
<tr>
<td>Fin spacing</td>
<td width="61">mm</td>
<td>1.3</td>
</tr>
<tr>
<td>Fin type</td>
<td width="61"></td>
<td>Hydrophilic aluminium</td>
</tr>
<tr>
<td>Tube outside dia.and type</td>
<td width="61">mm</td>
<td>Ф7,Inner groove tube</td>
</tr>
<tr>
<td>Coil length * height * width</td>
<td width="61">mm</td>
<td>900*22*609+865*22*609</td>
</tr>
<tr>
<td>Number of circuits</td>
<td width="61"></td>
<td>6</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor air flow</td>
<td>m3/h</td>
<td>3000</td>
</tr>
<tr>
<td colspan="2">Indoor sound power level</td>
<td>dB(A)</td>
<td>55</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor  sound pressure level</td>
<td>dB(A)</td>
<td>58</td>
</tr>
<tr>
<td colspan="2" width="269">Outdoor sound power level</td>
<td>dB(A)</td>
<td>68</td>
</tr>
<tr>
<td colspan="2" width="269">Throttle type</td>
<td width="61"></td>
<td>EXV+Capillary</td>
</tr>
<tr>
<td rowspan="3" width="135">Outdoor unit</td>
<td>Dimension(WxDxH)</td>
<td width="61">mm</td>
<td>890*342*673</td>
</tr>
<tr>
<td>Packing(WxDxH)</td>
<td width="61">mm</td>
<td width="200">1030*438*750</td>
</tr>
<tr>
<td>Net/Gross weight</td>
<td width="61">kg</td>
<td>48/51.8</td>
</tr>
<tr>
<td rowspan="3">Refrigerant</td>
<td>Type</td>
<td></td>
<td>R32</td>
</tr>
<tr>
<td>GWP</td>
<td></td>
<td>675</td>
</tr>
<tr>
<td>Charged quantity</td>
<td>Kg</td>
<td>1.85</td>
</tr>
<tr>
<td colspan="2" width="269">Design pressure</td>
<td width="61">MPa</td>
<td>4.3/1.7</td>
</tr>
<tr>
<td rowspan="5" width="135">Refrigerant piping</td>
<td width="134">Liquid side/ Gas side</td>
<td width="61">mm(inch)</td>
<td>3&#215;6.35mm(3&#215;1/4in)/3&#215;9.52mm(3&#215;3/8in)</td>
</tr>
<tr>
<td width="134">Max. length for all rooms</td>
<td width="61">m</td>
<td>60</td>
</tr>
<tr>
<td width="134">Max. length for one indoor unit</td>
<td width="61">m</td>
<td>30</td>
</tr>
<tr>
<td width="134">Max. height difference between indoor and outdoor unit</td>
<td width="61">m</td>
<td>15</td>
</tr>
<tr>
<td width="134">Max. height difference between indoor units</td>
<td width="61">m</td>
<td>10</td>
</tr>
<tr>
<td rowspan="2" width="135">Ambient temperature</td>
<td>Cooling</td>
<td width="61">℃</td>
<td>-15-50</td>
</tr>
<tr>
<td>Heating</td>
<td width="61">℃</td>
<td>-15-24</td>
</tr>